Product Details:
Payment & Shipping Terms:
|
Product Name: | Baby Digital Thermometer | Accuracy: | +/-0.1C |
---|---|---|---|
Measure Time:: | 1 Second | Usage: | Hospital Use |
Measuring Distance: | 3~5 Cm | Type: | Ear And Forehead Thermometer |
High Light: | non contact forehead thermometer,medical temperature gun |
Hospital Use Baby Digital Thermometer / Ear And Forehead Thermometer
Baby Digital Thermometer Specifications:
* Temperature range:-50 ~ 380℃ (-58~716℉)
* Accuracy:±1.5% or ±1.5℃
* Repeatability:±1% or ±1℃
* Distance Spot Ratio:12:1
* Emissivity:0.95 preset
* Resolution:0.1℃/℉
* Response Time:500ms
* Wavelength:8-14μm
* ℃/℉ Selection
* Data Hold function
* Laser Target Pointer selection
* Backlight ON/OFF selection
* Auto Power Shut Off
* Power supply:2*1.5V AAA battery
* Weight:115.1g(Including battery)
* Dimension:144.5*38*93mm
* Packing Method:Blister+Card
Baby Digital Thermometer Features
Product Name : | Baby digital thermometer |
Memory groups | 32*2 groups |
Product Dimensions | 14.3* 9.3* 3.8 CM |
Business type | Manufacturer |
Storage temperature | -20-50°C |
Storage Humidity | 15%-90%RH |
Operating temperature | 5-40°C |
Operating Humidity | 40%-85%RH |
Display | LCD crystal digital display |
Measuring method | Infrared radiation temperature measurement |
Measurement range | 32~42.5℃ fro human body, 0-100℃ for objects |
Resolution | 0.1 degrees Celsius (0.1 degrees Fahrenheit) |
Accuracy | 0-39.9kpa(0-299 mmhg) |
Voltage | 3 V |
Power consumption | < 3 mW |
Power supply | 2* AA battery |
Accessories Included | machine1, user manual*1, gift box |
Advice before use
Infrared forehead thermometers have high requirements on the surrounding environment. The correct method of use is the key to accurate testing.
(1) This product is an infrared forehead thermometer that professionally measures the temperature of the human body. According to the difffference of human skin, the measured temperature will be difffferent.
(2) When the room temperature changes greatly, the infrared frontal thermometer should be placed in the room for 20 minutes before use.
(3) When the person to be measured comes from a place with a large difffference in temperature from the measurement environment, they should stay in the test environment for at least 5 minutes, and wait until
the temperature is consistent with the environment before measuring.
(4) The environment around the person to be tested must be stable. Do not test in places with large air flflow such asfans and air outlets of air conditioners