Product Details:
Payment & Shipping Terms:
|
Product Name: | Forehead Infrared Thermometer | Accuracy: | High Accuracy |
---|---|---|---|
Measure Time:: | 1 Second | Usage: | Household |
Measuring Distance: | 3~5 Cm | Function: | Data Hold Function |
High Light: | medical temperature gun,no touch infrared thermometer |
High Accuracy Forehead Infrared Thermometer With Data Hold Function
Forehead Infrared Thermometer Introduction
This infrared thermometer is used for measuring the temperature of the object's surface, which is applicable for various hot, hazardous or hard-toreach objects without contact safely and quickly.
This unit consist of Optics, Temperature Sensor Signal amplifier, Processing circuit and LCD Display. The Optics collected the infrared energy emitted by object and focus onto the Sensor. Then the sensor translates the energy into an electricity signal. This signal will be turned out to be digital shown on the LCD after the signal amplifier and processing circuit.
Product Name : | High Accuracy Forehead Infrared Thermometer With Data Hold Function |
Memory groups | 32*2 groups |
Product Dimensions | 14.3* 9.3* 3.8 CM |
Business type | Manufacturer |
Storage temperature | -20-50°C |
Storage Humidity | 15%-90%RH |
Operating temperature | 5-40°C |
Operating Humidity | 40%-85%RH |
Display | LCD crystal digital display |
Measuring method | Infrared radiation temperature measurement |
Measurement range | 32~42.5℃ fro human body, 0-100℃ for objects |
Resolution | 0.1 degrees Celsius (0.1 degrees Fahrenheit) |
Accuracy | 0-39.9kpa(0-299 mmhg) |
Voltage | 3 V |
Power consumption | < 3 mW |
Power supply | 2* AA battery |
Accessories Included | machine1, user manual*1, gift box |
Advice before use
Infrared forehead thermometers have high requirements on the surrounding environment. The correct method of use is the key to accurate testing.
(1)This product is an infrared forehead thermometer that professionally measures the temperature of the human body. According to the difffference of human skin, the measured temperature will be difffferent.
(2) When the room temperature changes greatly, the infrared frontal thermometer should be placed in the room for 20 minutes before use.
(3) When the person to be measured comes from a place with a large difffference in temperature from the measurement environment, they should stay in the test environment for at least 5 minutes, and wait until
the temperature is consistent with the environment before measuring.
(4) The environment around the person to be tested must be stable. Do not test in places with large air flflow such asfans and air outlets of air conditioners
Precautions
Contact Person: Hou
Tel: +8615606578581